76
Sensor Calibration
Figure 93
Sensor Calibration Button
The Sensor Calibration button opens the Sensor Calibration window, where the Black
Mark and Label Gap sensors’ sensitivity can be enhanced.
The below table shows the range of the sensitivity enhancement setting of the two
sensors:
Sensor
Range
Label Gap
Sensor
0 (default) – 7 (max)
Black
Mark
Sensor
0 (default) – 50 (max)
The leftmost position of the slider corresponds to the factory settings and the represent
0 enhancement over those settings.
The bigger the value set on the sliders the more sensitive the sensors will be! The values
set here are saved with the Paper Profiles!
Figure 94
Sensor Calibration Sliders
Note:
Settings these values
to Max will likely result in constant false detection making the sensors unable to perform
their function. Please experiment in small increments! Every media type is different,
requires different sensitivity!