![RS PRO 917-6298 Instruction Manual Download Page 177](http://html.mh-extra.com/html/rs-pro/917-6298/917-6298_instruction-manual_1496054177.webp)
IIT-2000/2010/5000/5010 Instruction Manual/English
05/08/2015 Version No. 001
175
Syntax
Query Syntax
MANU:UTILity:ARCMode {OFF|ON_CONT| ON_STOP}
MANU:UTILity:ARCMode?
Parameter/
Return
parameter
OFF
Turns ARC mode off.
ON_CONT Sets ARC mode to ON and CONTINUE.
ON_STOP Sets ARC mode to ON and STOP.
Example
MANU:UTIL:ARCM OFF
Turns ARC mode OFF.
MANU:UTILity:PASShold
Set
Query
Description
Sets or returns the PASS HOLD setting for the current test.
Syntax
Query Syntax
MANU:UTILity:PASShold {ON|OFF}
MANU:UTILity:PASShold?
Parameter/
Return
parameter
OFF
Turns PASS HOLD off.
ON
Turns PASS HOLD on.
Example
MANU:UTIL:PASS OFF
Turns PASS HOLD OFF.
MANU:UTILity:FAILmode
Set
Query
Description
Sets or returns the FAIL mode setting for the current test.