74
15
Special Conditions of Safe Use (Explosion-proof Actuators)
In accordance with clause 5.1 of EN 60079-1, the critical dimensions of flamepaths relevant to
the EH1.1 are as follows:
Flamepath
Maximum Gap (mm)
Minimum L (mm)
Manifold Block/ Main Enclosure
(Flange Joint)
0.10
12.50
Control Knob Shaft/ Main Enclosure
(Cylindrical)
0.20
25.00
Terminal Bung/ Terminal Housing
(Cylindrical)
0.20
26.00
Indicator Shaft Bushing/ Main Enclosure
(Cylindrical)
0.00
25.25
Indicator Shaft/ Indicator Shaft Bushing
(Cylindrical)
0.20
31.75
Terminal Housing/ Main Enclosure
(Cylindrical)
0.15
26.20
Terminal Cover/ Terminal Housing
(Cylindrical)
0.15
14.70