![Ross Synergy 1 Maintenance Manual Download Page 35](http://html1.mh-extra.com/html/ross/synergy-1/synergy-1_maintenance-manual_1489025035.webp)
Synergy 1 and Synergy 100 Maintenance Guide (v16-S1)
System Architecture • 2–11
The MLE includes the following outputs:
•
Program
— This output is routed to a rear-frame BNC output connector, to the Preview
Matrix, and also back into the crosspoint matrix.
•
Preview
— This output is routed to a rear-frame BNC output connector and to the
Preview Matrix.
•
Clean Feed
— This output is routed to a rear-frame BNC output connector and also
back into the crosspoint matrix.
•
Aux 1
(Synergy 1 only)
— This output is routed to a rear-frame BNC output connector
through the video switch.
•
Aux 2
(Synergy 1 only)
— This output is routed to a rear-frame BNC output connector
through the video switch.
Serializer Modules
Program
,
Preview
,
Clean Feed, Aux 1,
and
Aux 2
video each come out of the MLE as parallel 10-bit
data.
These signals are then routed through small
Serializer Modules
(4000A-062) as shown below.
Serializer Module
Serializer Modules convert the parallel digital video data into the serial format, which can then be
routed via coax cables through your facility, or used internally in the Synergy’s crosspoint matrix.
The
crosspoint matrix requires that everything must be in the serial format.
Thus any signal that is routed
to the crosspoint matrix must go through a
Serializer Module
, from any given output.
Note
The
Clean Feed
has a dedicated BNC output, just like
Program
and
Preview
, but
DVE Send
is
only
available to the outside world by
routing it into the video switch, and then out via an Aux Bus.
There is no
DVE Send
BNC output.
Summary of Contents for Synergy 1
Page 1: ...Ross Video Limited Synergy 1 and Synergy 100 Maintenance Guide Software Version 16 S1...
Page 10: ......
Page 16: ...vi Contents Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 24: ...1 8 Introduction Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 70: ...3 24 Software Upgrades Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 108: ...5 12 Frame Processor CPU Board Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 122: ...6 14 Working with Installed Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 142: ...8 14 Power Supplies Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 172: ...9 30 Calibration and Diagnostics Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 186: ...10 14 Control Panel Boards Synergy 1 and Synergy 100 Maintenance Guide v16...
Page 230: ...13 20 Miscellaneous Options Synergy 1 and Synergy 100 Maintenance Guide v16 S1...
Page 240: ...IX 10 Index Synergy 1 and Synergy 100 Maintenance Guide v16 S1...