Remote Control Commands
R&S
®
SMBV100A
603
Operating Manual 1407.6062.32 ─ 08
Example:
BB:MCCW:TRIG:SOUR EXT
selects an external trigger via the TRIGGER 1 connector.
BB:MCCW:TRIG:INH 200
sets a restart inhibit for 200 samples following a trigger event.
[:SOURce<hw>]:BB:MCCW[:TRIGger]:SEQuence
<Sequence>
The command selects the trigger mode.
Parameters:
<Sequence>
AUTO | RETRigger | AAUTo | ARETrigger | SINGle
AUTO
The multi carrier signal is generated continuously.
RETRigger
The multi carrier signal is generated continuously. A trigger event
(internal or external) causes a restart.
AAUTo
The multi carrier signal is generated only when a trigger event
occurs. After the trigger event the signal is generated continu-
ously. Signal generation is stopped with command
SOURBB:MCCW:TRIG:ARM:EXEC
and started again when a trig-
ger event occurs.
ARETrigger
The multi carrier signal is generated only when a trigger event
occurs. The device automatically toggles to RETRIG mode. Every
subsequent trigger event causes a restart. Signal generation is
stopped with command
SOURBB:MCCW:TRIG:ARM:EXEC
and
started again when a trigger event occurs.
SINGle
The multi carrier signal is output only when a trigger event occurs.
After the trigger event the signal is output once to the set sequence
length (
SOURBB:MCCW:TRIG:SLEN
). Every subsequent trigger
event causes a restart.
*RST:
RETRigger
Example:
BB:MCCW:SEQ AAUT
sets the "Armed_auto" trigger mode; the device waits for the first
trigger (e.g. with
*TRG
) and then generates the signal continu-
ously.
Marker Settings
This section lists the remote control commands, necessary to configure the markers.
The marker delay settings are available for R&S SMx and R&S AMU instruments only.
..............................................604
SOURce Subsystem
Summary of Contents for SMBV100A
Page 31: ......