Remote Control Commands
R&S
®
SMBV100A
562
Operating Manual 1407.6062.32 ─ 08
Parameters:
<OnTime>
float
Range:
1 to 16777215
*RST:
1
Default unit: symbol
Example:
BB:DM:TRIG:OUTP2:ONT 20
sets an ON time of 20 symbols for marker 2
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PATTern
<Pattern>
The command defines the bit pattern used to generate the marker signal in the setting
SOURce:BB:DM:TRIGger:OUTPut:MODE PATTern
. 0 is marker off, 1 is marker on.
Parameters:
<Pattern>
integer
Range:
#B0,1 to #B111...1,32
*RST:
#B,1
Example:
BB:DM:TRIG:OUTP2:PATT #B000000011111111,15
sets a bit pattern.
BB:DM:TRIG:OUTP2:MODE PATT
activates the marker signal according to a bit pattern on output
MARKER 2.
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:DIVider
<Divider>
The command sets the divider for Pulse marker mode
(
SOUR:BB:DM:TRIGr:OUTP:MODE PULSe
). The resulting pulse frequency is derived
by dividing the symbol rate by the divider.
Parameters:
<Divider>
integer
Range:
2 to 1024
Increment: 1
*RST:
2
Example:
BB:DM:TRIG:OUTP2:PULS:DIV 2
sets the divider to 2 for the marker signal on output MARKER 2.
BB:DM:TRIG:OUTP2:FREQ?
queries the resulting pulse frequency of the marker signal.
Response: 66 000
the resulting pulse frequency is 66 kHz.
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:FREQuency?
The command queries the pulse frequency of the pulsed marker signal in the setting
SOURce:BB:DM:TRIGger:OUTPut:MODE PULSe
. The pulse frequency is derived by
dividing the symbol rate by the divider.
SOURce Subsystem
Summary of Contents for SMBV100A
Page 31: ......