Instrument Function
R&S
®
SMBV100A
367
Operating Manual 1407.6062.32 ─ 08
The resulting carrier gain in the carrier table equals:
Gai n* Gain Step
where n ranges from 0 to (Carrier Stop - Carrier Start).
SCPI command:
Phase Start
Sets the phase of the carrier marked by "Carrier Start".
SCPI command:
Phase Step
Sets the step width that is used to increment the phase.
The resulting phase in the carrier table equals:
Phas n* PhaseStep
where n ranges from 0 to (Carrier Stop – Carrier Start)
SCPI command:
Delay Start
Sets the delay of the carrier marked by "Carrier Start".
SCPI command:
Delay Step
Sets the step width that is used to increment the delay
The resulting delay in the carrier table equals:
Dela n* DelayStep
where n ranges from 0 to (Carrier Stop – Carrier Start).
SCPI command:
Input Waveform File
Calls the "File" menu for selecting the inputfile with the I/Q signal to be modulated onto
all carriers of the selected carrier range.
SCPI command:
Apply Assistant Settings
Transfer the assistant settings to the carrier table.
SCPI command:
Baseband Signal - Baseband Block