Instrument Function
R&S
®
SMBV100A
193
Operating Manual 1407.6062.32 ─ 08
External Input Impendance
(Source External only)
Selects the impedance for external feed via the EXT MOD input.
Selection 600 Ohm and high (>100 kOhm) is available.
Note:
This setting affects all analog modulations which use the external modulation
source.
SCPI command:
5.4.12.3
Frequency Modulation (FM)
An internal and/or external source can be selected for frequency modulation. The LF GEN
modulation generator is available as the internal source. Two-tone FM is possible by
simultaneously switching on the external and internal source.
The MOD EXT and PULSE EXT input connectors for external feed of analog modulation
signals are at the rear of the instrument. The coupling mode of the input (AC or DC) can
be selected.
Selection between three modulation modes is possible:
●
"Normal" mode with full setting range for modulation bandwidth and FM deviation.
●
"Low Noise" mode with better signal/noise ratio, but reduced setting range for mod-
ulation bandwidth
●
"High Deviation" mode with full setting range for FM deviation and a reduced setting
range for modulation bandwidth (see data sheet).
It is not possible to use frequency modulation simultaneously with phase modulation.
Frequency Modulation Settings
To open the "Frequency Modulation" menu, select "RF/A Mod > Configure > Frequency
Modulation" or use the MENU key under "RF/A Mod".
In the upper section of the menu, the modulation source is selected and the modulation
is switched on. The modulation source can be selected independently for the different
modulation types and the LF output.
The configuration of the selected external and/or internal modulation source is performed
in the lower section of the menu (internal source only).
These settings affect all modulations which use the same modulation sources.
RF Signal and Analog Modulations - RF Block
Summary of Contents for SMBV100A
Page 31: ......