Remote Control Commands
R&S
®
SMBV100A
645
Operating Manual 1407.6062.32 ─ 08
Parameters:
<Level>
float
Range:
-90 to 0
Increment: 0.01
*RST:
0
Default unit: dBFs
Example:
IQ:OUTP:DIG:POW:LEV -10
sets the output signal level to -10 dBFS.
Options:
B13 and B18
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:PEP
<Pep>
This command sets the peak envelope power of the digital output signal (PEP). The level
entry fields and the appropriate units (dBFS) are displayed in the status bar. The level
display refers to both signal components (√(I
2
+Q
2
).
Parameters:
<Pep>
float
Range:
-90 to 0
Increment: 0.01
*RST:
0
Default unit: dBFS
Example:
IQ:OUTP:DIG:POW:PEP -10
sets the signal output level to -10 dBFS.
Options:
B13 and B18
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP[:INCRement]
<Increment>
The command sets the step width for the frequency setting if the frequency values
UP/DOWN
are used and variation mode
SOUR:IQ:OUTP:DIG:POW:STEP:MODE USER
is selected. The command is linked to "Variation Step" for manual operation, i.e. the
command also sets the step width of the rotary knob for "Variation Active ON".
Parameters:
<Increment>
float
Range:
0 to 100
Increment: 0.01
*RST:
1
Default unit: dB
Example:
SOUR:IQ:OUTP:ANAL:POW:STEP:INCR 50 mV
sets the step width for the level setting to 50 mV.
Options:
B13 and B18