Instrument Function
R&S
®
SMBV100A
332
Operating Manual 1407.6062.32 ─ 08
The "Clock Settings" section is where the clock source is selected and - in the case of an
external source - the clock type.
The buttons in the last section lead to submenu for general trigger, clock and mapping
settings.
Trigger In
The "Trigger In" section is where the trigger for the signal is set. Various parameters will
be provided for the settings, depending on which trigger source - internal or external - is
selected. The current status of signal generation ("Running" or "Stopped") is indicated
for all trigger modes.
Trigger Mode
Selects trigger mode.
The trigger mode determines the effect of a trigger on the signal generation.
"Auto"
The signal is generated continuously.
"Retrigger"
The signal is generated continuously. A trigger event (internal or exter-
nal) causes a restart.
"Armed_Auto"
The signal is generated only when a trigger event occurs. Then the
signal is generated continuously.
Button "Arm" stops signal generation. A subsequent trigger event (inter-
nal with "Execute Trigger" or external) causes a restart.
"Armed_Ret-
rigger"
The signal is generated only when a trigger event occurs. Then the
signal is generated continuously. Every subsequent trigger event cau-
ses a restart.
Button "Arm" stops signal generation. A subsequent trigger event (inter-
nal with "Execute Trigger" or external) causes a restart.
Baseband Signal - Baseband Block
Summary of Contents for SMBV100A