Instrument Function
R&S
®
SMBV100A
356
Operating Manual 1407.6062.32 ─ 08
The sequencing list file carries information only about the segment number, the corre-
sponding wavefile names are retrieved form the assigned multi segment waveform file,
i.e. the same sequencing list file can be reused for different multi segment waveform files
with the same number of segments.
Changes and re-calculations of a multi segment waveform file cause a re-check whether
the assigned sequencing list files are still valid. A message is displayed to inform about
necessary corrections in the “play list”.
SCPI command:
n.a.
Assigned to Multi Seg. Waveform
Displays the name of the multi segment waveform file the current sequencing list file is
assigned to.
SCPI command:
n.a.
Sequencing Play List
The "Sequencing Play List" table is used to define the sequence in which the waveform
file segments are processed and how many times each of them is repeated.
Id# ← Sequencing Play List
Indication of the row number.
n.a.
State ← Sequencing Play List
Enables/disables the selected row. Only active segments are processed.
n.a.
Segment# ← Sequencing Play List
Indication of segment index.
The sequencing list file carries information only about the segment index, the corre-
sponding wavefile names are retrieved form the assigned multi segment waveform file.
n.a.
Waveform ← Sequencing Play List
Indication of the waveform file name of the segment. The file name is retrieved form the
assigned multi segment waveform file.
Available for selection are only waveform files from the pool of segments of the selected
multi segment waveform file.
n.a.
Repetition Cycles ← Sequencing Play List
Sets the number of times the selected segment is cyclically repeated before the next
segment in the sequence is processed.
n.a.
Baseband Signal - Baseband Block
Summary of Contents for SMBV100A
Page 31: ......