Remote control commands
R&S
®
NGP800
147
User Manual 5601.5610.02 ─ 09
TMC
USB TMC connection.
7.6
Measurement commands
The
MEASure
subsystem provides commands to query the voltage and current values
of a channel.
......................................................................................... 147
.................................................................................148
.................................................................................148
MEASure[:SCALar]:STATistic:COUNt?
............................................................................. 148
MEASure[:SCALar]:STATistic:RESet
................................................................................149
MEASure[:SCALar]:CURRent[:DC]?
................................................................................ 149
MEASure[:SCALar]:CURRent[:DC]:AVG?
.........................................................................149
MEASure[:SCALar]:CURRent[:DC]:MAX?
........................................................................ 149
MEASure[:SCALar]:CURRent[:DC]:MIN?
..........................................................................150
MEASure[:SCALar]:CURRent[:DC]:STATistic?
.................................................................. 150
........................................................................................... 150
....................................................................................150
................................................................................... 151
.................................................................................... 151
MEASure[:SCALar]:POWer:STATistic?
.............................................................................151
MEASure[:SCALar][:VOLTage][:DC]?
............................................................................... 151
MEASure[:SCALar][:VOLTage][:DC]:AVG?
........................................................................152
MEASure[:SCALar][:VOLTage][:DC]:MAX?
....................................................................... 152
MEASure[:SCALar][:VOLTage][:DC]:MIN?
........................................................................ 152
MEASure[:SCALar][:VOLTage][:DC]:STATistic?
................................................................. 152
READ?
Queries for the next available readback for voltage and current of the selected channel.
Example:
READ?
-> 1.00,0.00
Usage:
Query only
MEASure[:SCALar]:ENERgy?
[<Channel list>]
MEASure[:SCALar]:ENERgy??
[<Channel list>]
Queries the measured the current released energy value of the previous selected
channel.
Parameters:
<Channel list>
<list>
Example:
MEAS:ENER?
-> 5.382E+00 (value in Wh)
Measurement commands