Remote control commands
R&S
®
NGP800
148
User Manual 5601.5610.02 ─ 09
Example:
MEAS:ENER? (@1)
Queries the measured accumulated energy value at channel 1.
Usage:
Query only
MEASure[:SCALar]:ENERgy:RESet
[<Channel list>]
MEASure[:SCALar]:ENERgy:RESet
[<Channel list>]
Resets the energy counter for the selected channel.
Parameters:
<Channel list>
<list>
Example:
MEAS:ENER:RES (@1)
Resets the measured accumulated energy value at channel 1.
Usage:
Setting only
MEASure[:SCALar]:ENERgy:STATe
<arg0>[, <Channel list>]
MEASure[:SCALar]:ENERgy:STATe?
[<Channel list>]
Sets or queries the energy counter state for the selected channel.
Parameters:
<state>
1
Activates the energy counter.
0
Deactivates the energy counter.
Parameters for setting and query:
<Channel list>
<list>
Example:
INST OUT1
MEAS:ENER:STAT ON
MEAS:ENER:STAT?
MEAS:ENER:STAT?
-> 1
Energy counter of Ch1 is enabled.
Example:
MEAS:ENER:STAT? (@1)
Queries the energy counter state at channel 1.
MEASure[:SCALar]:STATistic:COUNt?
[<Channel list>]
MEASure[:SCALar]:STATistic:COUNt??
[<Channel list>]
Returns the number of samples measured in the statistics for voltage/current/power
Parameters:
<Channel list>
<list>
Example:
MEAS:STAT:COUN? (@1)
Queries the number of measurements at channel 1.
Usage:
Query only
Measurement commands