AirPick - Instruction Manual
700E
Cyclic Redundancy Check (CRC)
Response is: 09 04 04 F0 00 00 00 41 44
Bits
Description
09
Slave ID
04
Function Code 04 (Read Input Registers)
04
Number of data bytes to follow
F000
Content of register 07D0
0000
Content of register 07D1
4144
Cyclic Redundancy Check (CRC)
4.7.3. Preset single register (FC06)
Function code 06 (FC06) is used to activate functionalities of the Vacuum Gripper (robot output). It can be used to set registers
one at a time. Examples of use of these data are action request, maximum vacuum level, minimum vacuum level, etc.
Example of setting multiple registers FC06:
This message request sets the maximum relative pressure level.
Request is: 09 06 03 E9 00 19 95 A3
Bits
Description
09
Slave ID
06
Function Code 06 (Preset Single Registers)
03E9
Address of the requested register
0019
Value written in register 03E9 (Maximum pressure level = 75%)
98F8
Cyclic Redundancy Check (CRC)
Response is: 09 06 03 E9 00 19 95 A3
50
Summary of Contents for AirPick
Page 25: ...Fig 3 7 Mounting air nodes suction cups air bolts air nuts on the bracket 25...
Page 27: ...Fig 3 9 Robotiq Vacuum Gripper with pigtail cable and device cable wiring scheme 27...
Page 35: ...Fig 4 1 Vacuum Gripper control logic overview 35...
Page 57: ...7 Click on the New Project icon in the upper left corner of the screen 57...
Page 58: ...AirPick Instruction Manual 8 Enter a name for your program and click on the OK button 9 58...
Page 76: ...Fig 6 5 Minimum and maximum arrangement possibilities of the air nodes position 76...
Page 77: ...AirPick Instruction Manual 6 1 3 Air nodes Fig 6 6 Air nodes dimensions 77...
Page 103: ...AirPick Instruction Manual 12 Appendix Fig 12 1 Pneumatic schema of the AirPick Vacuum Gripper...