Cascade Installation Guide
74
To specify forwarding destinations,
1.
Go to the
Configuration
Flow Forwarding
page.
2.
Click
Add New Entry
to open a blank entry for specifying a destination
Profiler.
3.
Enter the destination IP address, port number, and data type for each
destination. (For IPFIX data, select NetFlow.)
4.
If you need to have the data identified as coming from the Gateway, select
Overwrite Source
to use the Gateway address as the source address in the
forwarded data packets.
5.
In the
Flow Sources
box, either:
•
Leave the box blank to forward all flow data to the specified device, or
•
Enter a comma-separated list of the IP addresses of flow source devices
whose traffic is to be sent to the specified destination device.
You can enter IP addresses by clicking
Browse
and searching for the flow
source device by name, address, or subnet.
6.
Click
Configure Now
at the bottom of the page to apply the settings.
The Gateway begins forwarding flow data to the destination devices within 5
minutes after you click
Configure Now
.
Verification
Complete the installation by:
1.
Verifying Gateway operation.
2.
Verifying that the Remote Management Module is accessible.
3.
Exiting the installation process.
Verifying Gateway operation
Verify that the Gateway has been successfully installed and configured by logging
in and checking the Overview page. The Overview page identifies all traffic
information sources that are currently sending data to the Gateway. Also, it
identifies destinations to which the Gateway forwards traffic information.