Cascade Installation Guide
46
5.
In the
RMM Settings
section, click
Set up RMM
. This opens a setup
page.
6.
Enter the factory preset username
admin
and password
password
in the
setup popup.
7.
Enter the RMM network interface IP address, netmask and gateway and
click
OK
.
8.
Check to ensure that the new RMM address information is displayed in the
RMM Settings
section.
9.
At the bottom of the
Setup
page, there is a checkbox labeled
Power down
after configuration
.
•
If the Sensor is mounted in the rack and you are ready to connect it to
the network, leave the
Power down after configuration
box
unselected and click
Configure Now
.
•
If the Sensor must be powered off and mounted in the rack before it
can be connected to the network, select the
Power down after
configuration
box and click
Configure Now
.
10.
When you click
Configure Now
, you will be prompted to change the
password. The password you enter here must be the one you use after this
point in the procedure. Enter your new password.
11.
When the password change operation is completed, exit from the browser
session and disconnect the crossover cable from the Sensor.
Additional configuration tasks, such as specifying the Profilers to which the
Sensor is to send data, can be performed by logging in to the Sensor GUI after it
is connected to the management network.
If the Sensor is mounted in the rack and ready to connect to the network, proceed
to the next section,
Network connections
.
If the Sensor still needs to be mounted, wait for it to power down and then mount
it in the rack as described in Section 3,
Mounting and powering
, before
proceeding to the next section,
Network connections
.