![Riverbed Cascade Express Installation Manual Download Page 68](http://html1.mh-extra.com/html/riverbed/cascade-express/cascade-express_installation-manual_1465706068.webp)
Cascade Installation Guide
58
6.
After the operation completes, click the name of the Sensor-VE monitor
interface (e.g., mon0) in the
VNI Name
column to display the details of the
connection.
7.
Ensure that all data flow rules options are set to
all
. The Sensor-VE should
monitor all traffic on the Steelhead LAN interfaces.
8.
Ensure that both the
Default IP Policy
and the
Default Non-IP Policy
lists
have the
Copy Traffic to Slot
option selected.
9.
Click
Apply
to complete the assignment for this interface and close the details
window.
10.
If the Steelhead has more than one LAN interface, then repeat this procedure
for each LAN interface. For example, navigate to:
Configure > Branch Services > RSP Data Flow inpath0_1
and continue with Step 2 above.
Configure the Sensor-VE management interface
Use RSP to specify the network address at which the Sensor-VE user interface
can be reached.
1.
If you are not still on the Configure > Branch Services > RSP Packages page,
then go to that page and, in the
Slots:
section, click the name or number for
the slot in which the Sensor-VE is installed to expand the entry.
Summary of Contents for Cascade Express