RIGOL
Chapter 2 Command Systems
Programming Guide for DSA1000A series
2-84
Function
Sets the bandwidth of the main channels, the default unit is Hz, such
as
:ACP:BAND:INT 1000000 or :ACP:BAND:INT 1MHZ
The query returns “1000000”.
Explanations
<freq> ranges from 33 Hz to 1 GHz.
Default
2 MHz
Front Panel
Meas, ACP
Meas Setup, Main CH BW
48.
[:SENSe]:ACPower:BANDwidth:ACHannel
Syntax
[:SENSe]:ACPower:BANDwidth:ACHannel <freq>
[:SENSe]:ACPower:BANDwidth:ACHannel?
Function
Sets the bandwidth of the adjacent channel, the default unit is Hz, such
as
:ACP:BAND:ACH 1000000 or :ACP:BAND:ACH 1MHZ
The query returns “1000000”.
Explanations
<freq> ranges from 33 Hz to 1 GHz.
Default
2 MHz
Front Panel
Meas, ACP
Meas Setup, Adj CH BW
49.
[:SENSe]:ACPower:CSPacing
Syntax
[:SENSe]:ACPower:CSPacing <freq>
[:SENSe]:ACPower:CSPacing?
Function
Sets the center frequency difference between the main and adjacent
channels, the default unit is Hz, such as
:ACP:BAND:CSP 1000000 or :ACP:BAND:CSP 1MHZ
The query returns “1000000”.
Explanations
<freq> ranges from 33 Hz to 1 GHz.
Default
2 MHz
Front Panel
Meas, ACP
Meas Setup, CH Spacing
50.
[:SENSe]:CHPower:AVERage:COUNt
Syntax
[:SENSe]:CHPower:AVERage:COUNt <integer>
[:SENSe]:CHPower:AVERage:COUNt?
Function
Sets the number of averages of the channel power measurement
Summary of Contents for DSA1000A Series
Page 1: ...RIGOL Programming Guide DSA1000A Series Spectrum Analyzer May 2011 RIGOL Technologies Inc...
Page 2: ......
Page 14: ......
Page 137: ...Chapter 3 Programming Examples RIGOL Programming Guide for DSA1000A series 3 3...
Page 154: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 20 6 Exit code...
Page 158: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 24...