Chapter 2 Command Systems
RIGOL
Programming Guide for DSA1000A series
2-75
The query returns
“900000000,0.300000,1000000000,0.350000,
1300000000,0.200000”.
Explanations
<n> is 1 (Antenna), 2 (Cable), 3 (Other) or 4 (User).
<freq> is related to the current analyzer model, the unit is Hz.
<rel_ampl> ranges from -120 dB to 100 dB.
The editable numbers of points range from 1 to 200.
Front Panel
AMPT, Corrections, Select, Off/Antenna/Cable/Other/User, Edit,
Point/Frequency/Amplitude/Del Point
9.
[:SENSe]:CORRection:CSET<n>:DATA:MERGe
Syntax
[:SENSe]:CORRection:CSET<n>:DATA:MERGe
<freq>,<rel_ampl>{,<freq>,<rel_ampl>}
Function
Adds new correction data upon the current correction curve.
Explanations
For detailed parameter information, please refer to
[:SENSe]:CORRection:CSET<n>:DATA.
10.
[:SENSe]:CORRection:CSET<n>:DELete
Syntax
[:SENSe]:CORRection:CSET<n>:DELete
Function
Deletes the correction settings.
Explanations
<n> is 1 (Antenna), 2 (Cable), 3 (Other) or 4 (User).
Front Panel
AMPT, Corrections, Select, Off/Antenna/Cable/Other/User, Delete
11.
[:SENSe]:CORRection:CSET<n>:X:SPACing
Syntax
[:SENSe]:CORRection:CSET<n>:X:SPACing LINear|LOGarithmic
[:SENSe]:CORRection:CSET<n>:X:SPACing?
Function
Sets the amplitude correction mode to Lin or Log.
Explanations
<n> is 1 (Antenna), 2 (Cable), 3 (Other) or 4 (User).
In Lin mode, the frequency uses linear and the amplitude uses
logarithm as the unit to make an interpolation operation.
In Log mode, both the frequency and amplitude use logarithm as
the unit to make an interpolation operation.
Default
LINear
Front Panel
AMPT, Corrections, Freq Interp, Log/
Lin
12.
[:SENSe]:CORRection:CSET<n>[:STATe]
Syntax
[:SENSe]:CORRection:CSET<n>[:STATe] OFF|ON|0|1
Summary of Contents for DSA1000A Series
Page 1: ...RIGOL Programming Guide DSA1000A Series Spectrum Analyzer May 2011 RIGOL Technologies Inc...
Page 2: ......
Page 14: ......
Page 137: ...Chapter 3 Programming Examples RIGOL Programming Guide for DSA1000A series 3 3...
Page 154: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 20 6 Exit code...
Page 158: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 24...