Chapter 2 Command Systems
RIGOL
Programming Guide for DSA1000A series
2-63
1.
:READ:ACPower?
Syntax
:READ:ACPower?
Function
The command executes a measurement and returns 5 values at
comma intervals:
Main channel power
Upper channel power, Power difference between upper and main
channel (dBc)
Lower channel power, Power difference between lower and main
channel (dBc)
Explanations
The power unit of returned value is the same as the unit of
Y-axis.
The command transmits the data from the latest measurement
to the ouput buffer.
Return Value such as
-5.01,
-5.01,
-2.301865E-01,
-5.01,7.757568E-02
2.
:READ:ACPower:LOWer?
Syntax
:READ:ACPower:LOWer?
Function
The command executes a measurement and returns the lower
channel power.
Explanations
The power unit of returned value is the same as the unit of
Y-axis.
The command transmits the data from the latest measurement
to the ouput buffer.
Return Value Such as -5.01
3.
:READ:ACPower:UPPer?
Syntax
:READ:ACPower:UPPer?
Function
The command executes a measurement and returns the upper
channel power.
Explanations
The power unit of returned value is the same as the unit of
Y-axis.
The command transmits the data from the latest measurement
to the ouput buffer.
Return Value Such as -5.01
Summary of Contents for DSA1000A Series
Page 1: ...RIGOL Programming Guide DSA1000A Series Spectrum Analyzer May 2011 RIGOL Technologies Inc...
Page 2: ......
Page 14: ......
Page 137: ...Chapter 3 Programming Examples RIGOL Programming Guide for DSA1000A series 3 3...
Page 154: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 20 6 Exit code...
Page 158: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 24...