Chapter 2 Command Systems
RIGOL
Programming Guide for DSA1000A series
2-117
return “UPPERL” and “LOWERL” respectively when the Pass/Fail
function is On.
Default
WRITe
Front Panel
Trace, Trace Type, Clear Write/Max Hold/Min Hold/Video Avg/Power
Avg/Freeze
13.
:TRACe:AVERage:CLEar
Syntax
:TRACe:AVERage:CLEar
Function
Clears the number of averages.
14.
:TRACe:AVERage:COUNt
Syntax
:TRACe:AVERage:COUNt <integer>
:TRACe:AVERage:COUNt?
Function
Sets the number of averages of the trace, such as
:TRAC:AVER:COUN 10
The query returns “10”.
Explanations <integer> ranges from 1 to 1000.
Default
100
Front Panel
Trace, Avg Num
15.
:TRACe:AVERage:COUNt:CURRent?
Syntax
:TRACe:AVERage:COUNt:CURRent?
Function
The query returns the current number of averages of the trace, such
as “1”.
16.
:TRACe<n>:AVERage:TYPE
Syntax
:TRACe<n>:AVERage:TYPE VIDeo|RMS
:TRACe<n>:AVERage:TYPE?
Function
Sets the average type of the trace.
The query returns “VID” or “RMS”.
Explanations
<n> is 1, 2 or 3.
The query of “:TRACe2:AVERage:TYPE?” and
“:TRACe3:AVERage:TYPE?” will return “ERR” when the
Pass/Fail function is On.
Default
VIDeo
Front Panel
Trace, Trace Type, Video Avg/Power Avg
Summary of Contents for DSA1000A Series
Page 1: ...RIGOL Programming Guide DSA1000A Series Spectrum Analyzer May 2011 RIGOL Technologies Inc...
Page 2: ......
Page 14: ......
Page 137: ...Chapter 3 Programming Examples RIGOL Programming Guide for DSA1000A series 3 3...
Page 154: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 20 6 Exit code...
Page 158: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 24...