RIGOL
Chapter 2 Command Systems
Programming Guide for DSA1000A series
2-14
The peak which has a smaller frequency compared with 1% of
span or the resolution bandwidth will be ignored.
When no desired peak is found, the system will show
“No peak
found”.
Front Panel
Method one: Peak, Peak Left
Method two: L-Peak
24.
:CALCulate:MARKer<n>:MAXimum:NEXT
Syntax
:CALCulate:MARKer<n>:MAXimum:NEXT
Function
Searches the peak whose amplitude is the closest to the current
peak‟s and meets the searching condition. The peak is then
identified with a marker
Explanations
<n> is 1, 2, 3 or 4.
The peak which has a smaller frequency compared with 1% of
span or the resolution bandwidth will be ignored.
When no desired peak is found, the system will show
“No peak
found”.
Front Panel
Peak, Next Peak
25.
:CALCulate:MARKer<n>:MAXimum:RIGHt
Syntax
:CALCulate:MARKer<n>:MAXimum:RIGHt
Function
Searches the nearest peak located to the right side of the current
peak and meets the searching condition. The peak is then identified
with a marker.
Explanations
<n> is 1, 2, 3 or 4.
The peak which has a smaller frequency compared with 1% of
span or the resolution bandwidth will be ignored.
When no desired peak is found, the system will show
“No peak
found”.
Front Panel
Method one: Peak, Peak Right
Method two: R-Peak
26.
:CALCulate:MARKer<n>:MINimum
Syntax
:CALCulate:MARKer<n>:MINimum
Function
Searches the peak with the minimum amplitude on the trace and
identifies it with a marker.
Explanations
<n> is 1, 2, 3 or 4.
Summary of Contents for DSA1000A Series
Page 1: ...RIGOL Programming Guide DSA1000A Series Spectrum Analyzer May 2011 RIGOL Technologies Inc...
Page 2: ......
Page 14: ......
Page 137: ...Chapter 3 Programming Examples RIGOL Programming Guide for DSA1000A series 3 3...
Page 154: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 20 6 Exit code...
Page 158: ...RIGOL Chapter 3 Programming Examples Programming Guide for DSA1000A series 3 24...