7.
Fill the air into the syringe to full.
Do not pull the syringe for air filling while it is being connected to the print head in order to prevent
from contamination of the print head.
8.
Connect the bypass tube connector (LF4131) to the syringe.
9.
Push the syringe in order to discharge the remained cleaning liquid of the print head.
(60ml air should be pushed out per 1-2second)
Connect the air
ejection tool to the air
purge port.
Connect the bypass
tube