T
echnical
B
ulletin
PAGE: 4/23
Model: Shepherd-Lt
Date: 7th
-Oct-19
No.:
RM0D4011
4.
Attach the air bubble ejection tool [A] at the maintenance station.
5.
Connect ONE tube of the air bubble ejection tool to the any port on the carriage.
Use only one tube to push out the cleaning liquid more strongly, though air bubble ejection tool has
2 tubes,
6.
Connect the bypass tube with the tube of the print head which has corresponding air purge
port. [B].
Connect the syringe tube assy to print head directly when using M1533053 or M0BY3200, after
filling the syringe with the air..
LM4131 connected
with tube of print head