T
echnical
B
ulletin
PAGE: 6/17
Model: Shepherd-Lt
Date:
14-Jun-19
No.:
RM0D4005
2. Installation>Main Machine Installation>Installation Procedure>Checking the Table
Surface Parallel
Step1 to Step3 are deleted because loopback connector is not bundled.
Checking the Table Surface Parallel
This section describes how to check the table surface parallel, and how to perform the adjustment.
The table surface parallel is checked by measuring the gap between the carriage and table surface at
72 points. When the measured results are not within a prescribed standard range, adjustment is
required.
Make sure that you have the following tools for checking the table surface parallel.
No.
Description
Q’ty
[A]
KEYENCE Sensor head (IL-S025)
1
[B]
KEYENCE Amplifier unit (IL-1000)
1
[C]
KEYENCE Sensor head cable (OP-87058)
1
[D]
KEYENCE power supply AC to DC (KZ-U3)
*1
1
[E]
Power cables with plug
1
*1 Available as common item
1.
Open the maintenance station rear cover [A].