T
echnical
B
ulletin
PAGE: 6/23
Model: Shepherd-Lt
Date: 7th
-Oct-19
No.:
RM0D4011
10.
Disconnect the syringe from the tube connector of syringe tool.
Disconnect the syringe tube assy when using M1533053 or M0BY3200.
11.
Repeat 3 times step 7 to 10 at one air purge port.
12. Repeat step 6 to 11 to all of the air purge port.
Pull out the tube while pressing the button
①
on the side of the ports.
Perform this procedure each one port individually in line with the port list shown below.
Print head configuration: Standard