T
echnical
B
ulletin
PAGE: 2/3
Model: Shepherd-P1, Shepherd-Lt
Date:
24-Oct-19
No.: RM0D4015
lit in green.
•
Take care the wiring route as follow below and fix the sensor cable by cable tie with the ionizer
cable inside the UV lamp cover, when installing the Encoder sensor cable.
Take care the wiring route[A] as without kink or without touch the X-axis frame.
Result of kink, the cable is touched and rubbed with the frame. (Red circle [B])
Good
Not Good (wire kinked)
Take care not to rub the sensor cable[A].
Sensor cable go through narrow space between the X-axis frame.
The bracket and the sensor cable move with carriage, so that check whether the
sensor cable doesn’t touch around the frame or X-axis slide rail when carriage is
moving.