No.
Definition
Symptom
Possible Cause
322
B
Laser synchronization error
The main scan synchronization detector
does not detect the laser signal for 0.5
second.
• Toner bottle not installed
• Loose connection between the LD unit
and the BICU
• Defective cable between the BICU
and LD unit
• LD unit out of position
• Defective LD unit
• Defective BICU
390
B
TD sensor error
The BICU detects the TD sensor outputting
extraordinary voltage (less than 0.2 V or
more than 4.0 V) 10 times consecutively.
• Defective TD sensor
• Loose connection of the PCU
391
B
Development bias leak
The polling module detects a current leak
of the development bias.
• Loose connection of the PCU
• Defective high voltage supply board
392
B
Developer initialization error
The ID sensor does not detect a correct
pattern during developer initialization
( 2-214-001).
• Defective ID sensor
• Insufficient developer
• Defective drum operation
• Defective development roller
operation
• Loose connection of the PCU
• Insufficient voltage for the charge
roller
SC Tables
155
6
Summary of Contents for S-C4.5
Page 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Page 2: ......
Page 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Page 134: ...4 Replacement and Adjustment 132 4...
Page 152: ...5 System Maintenance Reference 150 5...
Page 186: ...6 Troubleshooting 184 6...
Page 194: ...MEMO 192 EN...
Page 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Page 196: ......