Address
Function
Unit
Remarks
6805A3
Acceptable CED detection frequency
lower limit (high byte)
BCD (Hz)
If both addresses contain FF
(H), tone detection is
disabled.
6805A4
Acceptable CED detection frequency
lower limit (low byte)
6805A5
CED detection time
20 ms ± 20 ms Factory setting: 200 ms
6805A6
Acceptable CNG detection frequency
upper limit (high byte)
BCD (Hz)
If both addresses contain FF
(H), tone detection is
disabled.
6805A7
Acceptable CNG detection frequency
upper limit (low byte)
6805A8
Acceptable CNG detection frequency
lower limit (high byte)
BCD (Hz)
If both addresses contain FF
(H), tone detection is
disabled.
6805A9
Acceptable CNG detection frequency
lower limit (low byte)
6805AA
Not used
-
Do not change the setting.
6805AB
CNG on time
20 ms
Factory setting: 500 ms
6805AC
CNG off time
20 ms
Factory setting: 3000 ms
6805AD
Number of CNG cycles required for
detection
-
The data is coded in the same
way as address 680533.
6805AE
Not used
-
Do not change the settings.
6805AF
Acceptable AI short protocol tone
(800Hz) detection frequency upper limit
(high byte)
Hz (BCD)
If both addresses contain FF
(H), tone detection is
disabled.
6805B0
Acceptable AI short protocol tone
(800Hz) detection frequency upper limit
(low byte)
6805B1
Acceptable AI short protocol tone
(800Hz) detection frequency lower limit
(high byte)
Hz(BCD)
If both addresses contain FF
(H), tone detection is
disabled.
6805B2
Acceptable AI short protocol tone
(800Hz) detection frequency lower limit
(low byte)
NCU Parameters
219
5
Summary of Contents for S-C4.5
Page 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Page 2: ......
Page 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Page 134: ...4 Replacement and Adjustment 132 4...
Page 152: ...5 System Maintenance Reference 150 5...
Page 186: ...6 Troubleshooting 184 6...
Page 194: ...MEMO 192 EN...
Page 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Page 196: ......