5414
Access Mitigation
001
Mitigation On/Off
Switches on/off masking of continuously used IDs and passwords that are identical.
[0 to 1/0/1]
0: Off
1: On
002
Mitigation Time
Sets the length of time for excluding continuous access for identical user IDs and passwords.
[0 to 60/15/1 min.]
5415
Password Attack
001
Permissible Number
Sets the number of attempts to attack the system with random passwords to gain illegal
access to the system.
[0 to 100/30/1 attempt]
002
Detect Time
Sets the time limit to stop a password attack once such an attack has been detected.
[1 to 10/5/1 sec.]
5416
Access Info
001
User Max Num
Limits the number of users used by the access exclusion and password attack detection
functions.
[50 to 200/200/1 users]
002
Password Max Num
Limits the number of passwords used by the access exclusion and password attack detection
functions.
[50 to 200/200/1 passwords]
System Service Mode