Sensor
Connector
Message
Remarks
DF Original Set
Sensor
DF CN103
Paper jam
-
Sensor
(None)
Originals are not detected.
DF Registration
Sensor
DF CN103
Paper jam
-
SN
Originals are correctly transported.
Inverter Sensor
DF CN103
Paper jam
-
SN
(None)
-
Exit Sensor
DF CN103
Paper jam
-
SN
-
Front Door Switch
CN114
Right door open
-
SW
Front/Right door open
The message depends on which
circuit is open (white front; blue
right).
Right Door Switch
CN114
Right door open
-
SW
Right door open
-
CNxxx: The connector on the BICU board.
DF CNxxx: The connector on the DF connection board.
SN: The connector on the sensor.
SW: The connector on the switch.
PCU: The connector on the PCU.
Blown Fuse Conditions
All of these fuses are on the power supply unit.
Fuse
Rating
At main switch ON
120 V
220 – 240 V
FU1
15A/125V
8A/250 V
No response
FU2
5A/125V
2.5A/250V
No response
6. Troubleshooting