7
Not used
Do not change the setting.
System Switch 01 - Not used (Do not change the factory settings.)
System Switch 02 [SP No. 1-101-003]
No
FUNCTION
COMMENTS
0-1 Not used
Do not change these settings.
2
Force after transmission stall
0: Off
1: On
With this setting on, the machine resets itself automatically
if a transmission stalls and fails to complete the job.
3-5 Not used
Do not change these settings.
6-7
Memory read/write by RDS
Bit 7: 0, Bit 6: 0
Always disabled
Bit 7: 0, Bit 6: 1
User selectable
Bit 7: 1, Bit 6: 0
User selectable
Bit 7: 1, Bit 6: 1
Always enabled
(0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked out, but the
user can temporarily switch RDS on to allow RDS operations
to take place. RDS will automatically be locked out again
after a certain time, which is stored in System Switch 03.
Note that if an RDS operation takes place, RDS will not
switch off until this time limit has expired.
(1,1): At any time, an RDS system can access the machine.
System Switch 03 [SP No. 1-101-004]
No
FUNCTION
COMMENTS
0-7
Length of time that RDS is
temporarily switched on when bits 6
and 7 of System Switch 02 are set
to “User selectable”
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of System Switch 02
are set to “User selectable”.
The default setting is 24 hours.
System Switch 04 [SP No. 1-101-005]
Bit Switches
165
5
Summary of Contents for S-C4.5
Page 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Page 2: ......
Page 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Page 134: ...4 Replacement and Adjustment 132 4...
Page 152: ...5 System Maintenance Reference 150 5...
Page 186: ...6 Troubleshooting 184 6...
Page 194: ...MEMO 192 EN...
Page 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Page 196: ......