1103*
Fusing Idling
[0 = No / 1 = Yes]
1103 1
Enables or disables the contact-release control. The following table lists the results.
Setting
0 = No
1 = Yes
C-R control
Works
Does not work
Idling time
Shorter
Longer
Fusing quality
Lower
Higher
1105*
Fusing Temp Adj
Adjusts the target fusing temperature. Note that the thermistor is at the center of the hot
roller.
1105 1 Warm Up-Center
[140 to 180 / 160 / 1°C/step]
1105 3 Standby-Center
[140 to 160 / 150 / 1°C/step]
1105 5 Copying-Center
[140 to 180 / 160 / 1°C/step]
1105 7 Low Level 2-Center
[0 to 80 / 60 / 1°C/step]
1105 9 Thick-Center
[140 to 185 / 165 / 1°C/step]
1106
Display Fusing
1106 1 (Center) Displays the fusing temperature.
1107*
Fusing Soft Start DFU
Adjusts the number of zero-cross cycles of the fusing lamp AC supply needed to bring the
fusing lamp power to 100% while bringing the lamp up to the standby temperature or while
copying. Increase this value if the machine is experiencing sudden power dropouts.
1107 1 Warm Up Soft Start
[0 = 10 times / 1 = 20 times / 2 = 50 times]
1107 2 Other Soft Start
[0 = 10 times / 1 = 20 times / 2 = 50 times / 3 = 1 time]
1107 3 Soft Stop Setting
[0: No / 1: Yes]
1108*
Set-Fusing Start
[0 = 1s / 1 = 1.5s / 2 = 2s]
1108 1 Specifies the interval for fusing-temperature control.
3. Appendix: SP Mode Tables
20
3
Summary of Contents for S-C4.5
Page 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Page 2: ......
Page 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Page 134: ...4 Replacement and Adjustment 132 4...
Page 152: ...5 System Maintenance Reference 150 5...
Page 186: ...6 Troubleshooting 184 6...
Page 194: ...MEMO 192 EN...
Page 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Page 196: ......