• Multiply this by the power consumption spec for each mode.
• Convert the result to kWh (kilowatt hours)
Here is an example calculation.
Machine
Date
Power
Consumption
(W):
Data: a
SP8941:
Machine
Status
Start Time:
(min.)
Data: b
End Time:
(min.)
Data: c
Time
Differences
(Data:b -
Data: c)
(min.)
Data: d
Power
Consumption
(Data:a x
Data:d)
(Wmin.)
Data: e
Operating
mode
1081.8
001:
Operating
Time
21089.0
21386.0
297.0
321294.6
Ready
mode
(stand by)
214.0
002:
Standby
Time
306163.0 308046.0
1883.0
402962.0
Energy
mode
(Panel off)
214.0
003:
Energy
Save Time
71386.0
75111.0
3725.0
797150.0
Low power
mode
153.0
004:
Low
power
Time
154084.0 156340.0
2256.0
345168.0
Off/Sleep
mode
7.0
005:
Off mode
Time
508776.0 520377.0
11601.0
81207.0
Total Time of Data: d (min.)
19762.0
Total Time of Data: d/60min. (Hour)
329.37
Total Power Consumption of Data: e (Wmin.)
1947781.60
Total Power Consumption of Data: e /60min./1000W (KWH)
32.46
Energy Save
187
7
Summary of Contents for S-C4.5
Page 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Page 2: ......
Page 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Page 134: ...4 Replacement and Adjustment 132 4...
Page 152: ...5 System Maintenance Reference 150 5...
Page 186: ...6 Troubleshooting 184 6...
Page 194: ...MEMO 192 EN...
Page 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Page 196: ......