7
Select detection of reverse polarity
in ringing
0: Off
1: On
This switch is used to prevent reverse polarity in ringing on
the phone line (applied to PSTN-G3 ringing). Do not
change this setting
0: No detection Outside Japan
1: Detection Inside Japan only
G3 Switch 04 [SP No. 1-105-005]
No
FUNCTION
COMMENTS
0-3
Training error detection threshold 0 - F (Hex); 0 - 15 bits
If the number of error bits in the received TCF is below this
threshold, the machine informs the sender that training has
succeeded.
4-7
Not used
Do not change the settings.
G3 Switch 05 [SP No. 1-105-006]
No
FUNCTION
COMMENTS
5. Appendix: Fax Service Program