7
Action when a fax SC has occurred
0: Automatic reset
1: Fax unit stops
0: When the fax unit detects a fax SC code other than
SC1201 and SC1207, the fax unit automatically resets
itself.
1: When the fax unit detects any fax SC code, the fax unit
stops.
Cross Reference
Fax SC codes - See “Troubleshooting”
I-Fax Switches
I-fax Switch 00 - Not used (do not change the settings) [SP No. 1-102-001]
I-fax Switch 01 [SP No. 1-102-002]
No
FUNCTION
COMMENTS
Original Line Resolution of TX
Attachment File
These settings set the maximum resolution of the original that
the destination can receive.
0
200x100 Standard
0: Not selected
1: Selected
If more than one of these three bits is set to “1”, the higher
resolution has priority. For example, if both Bit 0 and Bit 2
are set to “1” then the resolution is set for "Bit 2 200 x 400.
1
200x200 Detail
2
200x400 Fine
3
300 x 300 Reserve
4
400 x 400 Super Fine
5
600 x 600 Reserve
6
Reserve
Bit Switches
175
5
Summary of Contents for S-C4.5
Page 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Page 2: ......
Page 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Page 134: ...4 Replacement and Adjustment 132 4...
Page 152: ...5 System Maintenance Reference 150 5...
Page 186: ...6 Troubleshooting 184 6...
Page 194: ...MEMO 192 EN...
Page 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Page 196: ......