17 January, 2003
PRINTER ENGINE SERVICE MODE
5-69
Service
Tables
7
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
37
R(%): PCU [K]
38
R(%): PCU [Y]
39
R(%): PCU [M]
40
R(%): PCU [C]
41 R(%):
Dev
[K]
42 R(%):
Dev
[Y]
43 R(%):
Dev
[M]
44 R(%):
Dev
[C]
45 R(%):
Oil
Spply
46 R(%):
Fusing
Displays the value given by the following formula:
(Current revolution
÷
Target revolution)
×
100,
where “Current revolution” is the current value for
the counter of the part, and “Target revolution” is
the values of SP7-803-17 through 27. This shows
how much of the unit’s expected lifetime has been
used up.
The R% counter is based on rotations, not prints.
If the number of rotations reaches the limit, the
machine enters the end condition for that unit. If
the print count lifetime is reached first, the
machine also enters the end condition, even
though the R% counter is still less than 100%.
Oil supply unit: When the R% counter reaches
100%, it enters the near-end condition, not the
end condition. The end condition occurs some
number of rotations after this (not adjustable).
NOTE:
The machine internally adjusts or
compensates as necessary, depending on
conditions of machine usage. Due to this,
at the oil supply unit near-end condition,
the R% counter of the oil supply unit can
be 100%, lower than 100%, or higher than
100%.
47
S: Trans Cln
803
48
R: Trans Cln
*BCU
[PM Clear]
PM Counter Clear
(Unit, [Color])
Dev.: Development Unit, PF: Paper Feed Rollers, Transfer: Transfer Unit
1 PCU
[K]
2 PCU
[Y]
3 PCU
[M]
4 PCU
[C]
5 Dev.
[K]
6 Dev.
[Y]
7 Dev.
[M]
8 Dev.
[C]
9 Oil
Supply
10 PF
By-pass
11
PF Tray 1
12
PF Tray 2
13
PF Tray 3
14
PF Tray 4
15 Fusing
16 Transfer
17 Trans
Cln
804
50 All
Clears the PM counter.
Press the Enter key after the machine asks
“Execute?”.
When a unit is replaced, the machine
automatically detects that the new unit is installed.
Then, the current PM counter value is
automatically moved to the b PM Counter -
Previous (SP7-906-1 to 25) and is reset to “0”.
NOTE:
The LCT is counted as the 3rd feed
station.
[SC/Jam Clear]
SC/Jam Counter Clear
807
1
SC/Jam Clear
Clears the counters related to SC codes and
paper jams.