17 January, 2003
PRINTER ENGINE SERVICE MODE
5-15
Service
Tables
1
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
[Fusing Temp.]
Fusing Temperature
(
H
eating or
P
ressure roller: Paper Type, [Color],
S
implex/
D
uplex, Process Speed)
Paper Type -> N: Normal, OHP. TH: Thick, SP: Special
Some settings of fusing temperature depend on the destination (US or Europe/Asia).
US: Setting for US, EU: Setting for Europe/Asia
1 H: Ready
*BCU Sets the heating roller temperature for the printing
ready condition.
After the main switch has been turned on, the
machine enters the print ready condition when the
heating roller temperature reaches the
temperature specified in this SP mode.
When the machine is in the recovery mode from
the energy saver or auto off mode, the machine
becomes ready when both heating and pressure
roller temperatures reach the specified
temperature.
Ready temperature = (Target temperature
specified in SP1-104-25 or 105-3 to 28) –
Temperature specified in this SP mode.
[ 10 to 100 / 10 / 1
o
C/step ]
2 P: Ready
*BCU Sets the pressure roller temperature for the
printing ready condition.
Ready temperature = (Target temperature
specified in SP1-104-25 or 105-3 to 28) –
Temperature specified in this SP mode
[ 10 to 100 / NA: 10, EU: 20 / 1
o
C/step ]
The following SPs set the target operating temperatures of the heating and pressure
rollers in various modes. (The default settings are different for N. America and Eur./Asia)
4 H:N [K] S 125
*BCU [ 100 to 190 / NA: 170, EU: 175 / 5
°
C/step]
5 H:N [K] S 185
*BCU [ 100 to 190 / 180 / 5
°
C/step]
6 H:N [K] D 125
*BCU [ 100 to 190 / NA: 160, EU: 165 / 5
°
C/step]
7 H:N [K] D 185
*BCU [ 100 to 190 / NA: 170 , EU: 175 / 5
°
C/step]
8 H:N[FC]
S
62.5
*BCU [ 100 to 190 / NA: 145, EU: 150 / 5
°
C/step]
9 H:N[FC]
S
125
*BCU [ 100 to 190 / 180 / 5
°
C/step]
10 H:N[FC]
D
62.5
*BCU [ 100 to 190 / NA: 140, EU: 145/ 5
°
C/step]
11 H:N[FC]
D
125
*BCU [ 100 to 190 / NA: 160, EU: 170 / 5
°
C/step]
13 H:OHP
*BCU [ 100 to 190 / 165 / 5
°
C/step]
15 P:N [K] S 125
*BCU [ 0 to 190 / NA: 145, EU: 155 / 5
°
C/step]
16 P:N [K] S 185
*BCU [ 0 to 190 / NA: 150, EU: 160 / 5
°
C/step]
17 P:N [K] D 125
*BCU [ 0 to 190 / NA: 135, EU: 145 / 5
°
C/step]
18 P:N [K] D 185
*BCU [ 0 to 190 / NA: 140, EU: 155 / 5
°
C/step]
19 P:N[FC]
S
62.5
*BCU [ 0 to 190 / NA: 125, EU: 130 / 5
°
C/step]
20 P:N[FC]
S
125
*BCU [ 0 to 190 / 160 / 5
°
C/step]
21 P:N[FC] D 62.5
*BCU [ 0 to 190 / NA: 120, EU: 125 / 5
°
C/step]
22 P:N[FC] D 125
*BCU [ 0 to 190 / NA: 135, EU: 150 / 5
°
C/step]
24 P:OHP
*BCU [ 0 to 190 / 150 / 5
°
C/step]
26 H:TH
*BCU [ 0 to 190 / 175 / 5
°
C/step]
28 P:TH
*BCU [ 0 to 190 / 155 / 5
°
C/step]
29 H:Envelop
*BCU [ 0 to 190 / 175 / 5
°
C/step]
105
30 P:Envelop
*BCU [ 0 to 190 / 155 / 5
°
C/step]