PRINTER ENGINE SERVICE MODE
17 January, 2003
5-18
1
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
4 Mode 1 OHP narrow
914-2).
Second step (also called 'Mode 2'): After 20
sheets (SP 1-913-7), temperature drops by 10C
(SP 1-914-7).
Narrow: LT/A4 SEF width or less
Wide: Wider than LT/A4 SEF
[ 1 to 255 / 5 / 1 sheet/step ]
5 Mode 1 185 wide
[ 1 to 255 / 10 / 1 sheet/step ]
6 Mode 2 185
[ 1 to 255 / 20 / 1 sheet/step ]
7 Mode 2 125
[ 1 to 255 / 20 / 1 sheet/step ]
8 Mode 2 62.5
[ 1 to 255 / 20 / 1 sheet/step ]
9 Mode 2 185 narrow
[ 1 to 255 / 10 / 1 sheet/step ]
913
10 Mode 2 185 wide
*
[ 1 to 255 / 20 / 1 sheet/step ]
[Temp. Cor. 2]
Fusing Temperature Correction (Temperature Setting)
1 Temp 1 185
*BCU Specifies the temperature to be subtracted from
the targeted temperatures specified in SP1-105-4
to-24.
Narrow: LT/A4 SEF width or less
Wide: Wider than LT/A4 SEF
[ 0 to 20 / 0 / 5
°
C /step ]
2 Temp 1 125
*BCU [ 0 to 20 / 5 / 5
°
C /step ]
3 Temp 1 62.5
*BCU [ 0 to 20 / 0 / 5
°
C /step ]
4 Temp 1 OHP narrow
*BCU [ 0 to 20 / 5 / 5
°
C /step ]
5 Temp 1 OHP wide
*BCU [ 0 to 20 / 5 / 5
°
C /step ]
6 Temp 2 185
*BCU [ 0 to 20 / 10 / 5
°
C /step ]
7 Temp 2 125
*BCU [ 0 to 20 / 10 / 5
°
C /step ]
8 Temp 2 62.5
*BCU [ 0 to 20 / 10 / 5
°
C /step ]
9 Temp 2 OHP narrow
*BCU [ 0 to 20 / 5 / 5
°
C /step ]
914
10 Temp 2 OHP wide
*BCU [ 0 to 20 / 5 / 5
°
C /step ]
[Stand-by Time]
1 Job Receiving
*BCU Specifies the time to shift the machine into the
stand-by mode when not receiving a print start
command after receiving a print preparation
command.
[ 0 to 180 / 60 / 10 seconds/step ]
0: The machine does not shift to the stand-by
mode.
915
2 Job End
*BCU Specifies the time to shift the machine into the
stand-by mode after the last job is completed.
[ 0 to 180 / 30 / 10 seconds/step ]
0: The machine does not shift to the stand-by
mode.
[Idling Mode]
1 Mode Set
*BCU Executes the extra idling operation after the fusing
unit becomes ready just after the main switch has
been turned on.
[ 0 to 1 / 0 / 1 /step ]
0: Off
1: On
916
2 Idling Time
*BCU Specifies how long the extra idling operation is
executed.
[ 10 to 120 / 30 / 10 sec/step ]