17 January, 2003
PRINTER ENGINE SERVICE MODE
5-57
Service
Tables
5
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
22 Interrupt
*BCU Specifies the number of sheets to be printed
before a line position adjustment is done during a
print job.
[ 10 to 250 / 100 / 10 sheets/step ]
SP 5-993-4 must be set to ‘enabled’.
When the temperature difference meets the
conditions specified in SP5-993-3, the machine
starts counting the number of prints in the job. The
machine interrupts the print job and does the line
position adjustment if the number of prints
exceeds the number specified in this SP mode.
If the counted number of prints does not exceed
the number specified, the machine resets the
counter, then continues to monitor the
temperature and does the line position adjustment
next time.
24 Mscan Lgth Det
*BCU Performs the main scan length detection when the
polygon motor has operated consecutively for the
time specified in this SP mode.
[ 100 to 990 / 211 / 10 sec/step ]
25 Drm Gear Phase
*BCU Adjusts the phases of the black drum gear and the
color drum gear.
[ 0 to 345 / 0 / 15 degrees/step]
DFU
26 Initialization
*BCU Enables or disables the line position adjustment
during initialization.
[ 0 to 1 / 1 / 1/step]
0: Disable
1: Enable
993
27 Toner Refresh
*BCU Enables or disables the toner refreshing operation.
[ 0 to 1 / 1 / 1/step]
0: Disable
1: Enable
Repetitive line position adjustments can cause
abnormal outputs such as white spots. To prevent
this, toner is consumed and supplied after line
position adjustment.
[Unit Set]
Maintenance Unit Detection ON/OFF
1 Dev/PCU
*BCU
#
Enables or disables PCU and development unit
detection.
[ 0 or 1 / 0 / - ] Alphanumeric
0: Enable
1: Disable
NOTE:
If this mode is disabled, new unit detection
also does not function. Use this mode as a
temporary measure, only when the micro-
switches are defective.
994
2 Oil
Unit
*BCU
#
This is for the oil supply unit only, and not the
fusing unit
[ 0 or 1 / 0 / - ] Alphanumeric
0: Enable
1: Disable
NOTE:
Use this mode as a temporary measure,
only when the unit detection mechanism is
defective.