17 January, 2003
PRINTER ENGINE SERVICE MODE
5-29
Service
Tables
2
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
9
OHP LT SEF
*BCU [ 1.0 to 4.0 / 1.4 / 0.1/step ]
309
10 OHP A5 SEF
*BCU [ 1.0 to 4.0 / 4.0 / 0.1/step ]
[Transfer Ctrl]
Transfer Control
1
C Mode Posit
*BCU Adjusts the transfer belt position for color printing.
[ 0 to 500 / 170 / 10/step ]
DFU
SP2-402-1 is valid only when auto correct (SP2-
402-2) is disabled (
☛
6.7.5).
2
Auto Correct
*BCU Enable or disable the auto-adjustment of the
transfer belt position.
[ 0 to 1 / 1 / 1/step ]
DFU
0: Disabled
1: Enabled
•
When SP2-402-2 is enabled, the transfer belt
position for color printing is decided in
accordance with the result of the initialization
processing (
☛
6.7.5).
•
SP2-402-2 validates the setting of SP2-402-1,
but does not affect the setting of SP2-402-3.
402
3
Bk Mode Posit
*BCU Adjusts the transfer belt position for monochrome
printing.
[ 0 to 500 / 130 / 10/step ]
DFU
SP2-402-3 is always valid regardless of the setting
in SP2-402-2.
[PA Roller Cur.]
Paper Attraction Roller Current
([Color],
S
implex or
D
uplex, Process Speed): Current Adjustment
(
P
aper or
B
y-pass): Paper Size Correction
Adjusts the paper attraction roller current for color printing.
If paper misfeeds occur at the transfer unit in color mode, check and/or adjust the paper
attraction roller current.
NOTE:
The magenta development section is close to the paper attraction roller.
Decreasing the current may not cause paper misfeed.
If the current is increased too much, the following image problems may occur depending
on the humidity.
High humidity:
Insufficient image transfer in magenta due to current flow to the magenta OPC drum
Low humidity:
Offset image in magenta halftone areas due to paper charged positive too much
When adjusting the current with this SP mode, the value should be lower than transfer
current.
6 [FC]
S
62.5
*BCU [ 0 to 50 / 1 / 1
µ
A/step ]
7 [FC]
S
125
*BCU [ 0 to 50 / 1 / 1
µ
A/step ]
8
[FC] D 62.5
*BCU [ 0 to 50 / 5 / 1
µ
A/step ]
9
[FC] D 125
*BCU [ 0 to 50 / 10 / 1
µ
A/step ]
14 [K] B TH S
*BCU [ 10 to 30 / 5 / 0.1/step ]
15 [FC] B TH S
*BCU [ 10 to 30 / 1 / 0.1/step ]
16 [K] B OHP
*BCU [ 10 to 30 / 5 / 0.1/step ]
17 [FC] B OHP
*BCU [ 10 to 30 / 1 / 0.1/step ]
18 [K] B TH D
*BCU [ 10 to 30 / 5 / 0.1/step ]
19 [FC] B TH D
*BCU [ 10 to 30 / 1 / 0.1/step ]
20 [K] SP S
*BCU [ 10 to 30 / 8 / 0.1/step ]
21 [K] SP D
*BCU [ 10 to 30 / 12 / 0.1/step ]
801
22 [FC] SP S 62.5