17 January, 2003
PRINTER ENGINE SERVICE MODE
5-47
Service
Tables
5
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
[Memory Clear]
NOTE
: For more information, see “NOTE 1” following this table.
3 SCS
Clears the system settings.
4 IMH
CF Clears IMH data.
DFU
5 MCS
CF Clears MCS data.
DFU
6 Copy Application
CF Clears the copy application settings.
7 Fax Application
CF Clears the fax application settings.
8 Printer Application
Clears the printer application settings.
9 Scanner Application
CF Clears the scanner application settings.
10 Netfile Application
CF Delete the netfile application management files
and thumbnails, and initializes the job login ID.
11 NCS
Initializes the system default and interface settings
(IP address also), SmartNetMonitor for
Admin, WebStatusMonitor settings, and the
TELNET settings.
12 IPU
CF Clears the IPU settings
801
13 R-FAX
CF Initializes the job login ID, SmartNetMonitor for
Admin, job history, and local storage file numbers.
EngineFreeRun
802
1 EngineFreeRun
Performs a free run on the printer engine.
NOTE:
•
The machine starts free run in the same
condition as the sequence of A4/LT printing
from the 1st tray. Therefore, paper should be
loaded in the 1st tray, but paper is not fed.
•
The main switch has to be turned off and on
after using the free run mode for a test.
803
[Input Check]
See section 5-3-2.
804
[Output Check]
See section 5-3-3.
[Destination]
Destination Code Display
808
1 Destination
*BCU Displays the destination code.
[SC OFF]
SC Detection ON/OFF
809
1 SC ON/OFF
*BCU Enable or disables the service call detection (SC
codes will be ignored if disabling this SP mode).
[ 0 or 1 / 0 / - ] Alphanumeric
0: Enable
1: Disable
[SC Reset]
810
1 SC Reset
Resets a type A service call condition.
NOTE:
Turn the main switch off and on after
resetting the SC code.
[SN Display]
Serial Number Display
811
2 SN Display
*BCU Displays the machine serial number.
[FAX TEL No.]
812
1 Telephone
*
CTL
CF
Sets the telephone number for a service
representative. This number is printed on the
Counter List, which can be printed with the user’s
“Counter” menu.
This can be up to 20 characters (both numbers
and alphabetic characters can be input).