[0~1/0/1]
0: Off
1: On
5302
Set Time DFU
Sets the time clock for the local time. This setting is done at the factory before delivery. The
setting is GMT expressed in minutes.
[–1440~1440/1 min.]
JA: +540 (Tokyo)
NA: -300 (NY)
EU: +6- (Paris)
CH: +480 (Peking)
TW: +480 (Taipei)
AS: +480 (Hong Kong)
5307
Summer Time
Lets you set the machine to adjust its date and time automatically with the change to Daylight
Savings time in the spring and back to normal time in the fall. This SP lets you set these items:
- Day and time to go forward automatically in April.
- Day and time to go back automatically in October.
- Set the length of time to go forward and back automatically.
The settings for 002 and 003 are done with 8-digit numbers:
Digits
Meaning
1st, 2nd
Month. 4: April, 10: October (for months 1 to 9, the first digit of 0 cannot be
input, so the eight-digit setting for 002 or 003 becomes a seven-digit setting)
3rd
Day of the week. 0: Sunday, 1: Monday
4th
The number of the week for the day selected at the 3rd digit. If “0” is selected
for “Sunday”, for example, and the selected Sunday is the start of the 2nd
week, then input a “2” for this digit.
5th, 6th
The time when the change occurs (24-hour as hex code).
Example: 00:00 (Midnight) = 00, 01:00 (1 a.m.) = 01, and so on.
7th
The number of hours to change the time. 1 hour: 1
5. Service Tables
208
5
Summary of Contents for A-P4
Page 1: ...Model A P4 Machine Code G147 SERVICE MANUAL May 12th 2006 Subject to change...
Page 27: ...Installation Flowchart 1 Installation 26 1...
Page 59: ...3 Reattach the application cover x1 1 Installation 58 1...
Page 65: ...2 Preventive Maintenance 64 2...
Page 72: ...Left Covers 1 Left upper cover A x4 2 Controller cover B x2 Covers and Common Procedures 71 3...
Page 82: ...Laser Unit 81 3...
Page 103: ...5 Cover C x2 6 Gear D x1 7 Lower paper feed unit E x2 x1 3 Replacement and Adjustment 102 3...
Page 128: ...Duplex Unit Duplex Cover Removal 1 Duplex unit cover A x4 Duplex Unit 127 3...
Page 181: ...4 Troubleshooting 180 4...
Page 289: ...Self Diagnostic Test Flow 5 Service Tables 288 5...
Page 306: ...Controller Block Diagram Board Layout 305 6...
Page 319: ...What Happens When a New Unit Is Detected 6 Details 318 6...
Page 367: ...6 Details 366 6...
Page 379: ...MEMO 378...
Page 380: ...MEMO 379...
Page 381: ...MEMO 380...