The bus is being held by another de-
vice, or a CPU-device infinite loop has
occurred. A module that the watchdog
is monitoring has not closed properly
at the conclusion of its task, or the mod-
ule cannot continue processing.
• System program defective; switch off/on,
or change the controller firmware if the
problem cannot be solved
• Controller board defective
• Controller option malfunction
819
C
Fatal kernel error
Due to a control error, a RAM overflow occurred
during system processing. One of the following
messages was displayed on the operation panel.
• System program defective
• Controller board defective
• Optional board defective
• Replace controller firmware
0x696e
"init died"
0x766d
"vm_pageout: VM is full"
4361
Cache Error
Other
For more details about this SC code error, execute SP5990 to print an SMC report so you can read the
error code. The error code is not displayed on the operation panel.
820
D
Self-Diagnostic Error: CPU
• Controller board defective
• Firmware defective
• Update firmware
Note: This SC also logs one of 47 hex
codes (0001 to 4005). However, the re-
covery procedure is the same in each case.
The central processing unit returned an un-
expected error during the self-diagnostic
test.
821
D
Self-diagnostic error 2: ASIC
The Write & Verify check of the ASIC re-
turned an error.
Note: The main ASIC module on the con-
troller board controls the bus of the ROM
device.
• Replace the controller board
Service Call Conditions
163
4
Summary of Contents for A-P4
Page 1: ...Model A P4 Machine Code G147 SERVICE MANUAL May 12th 2006 Subject to change...
Page 27: ...Installation Flowchart 1 Installation 26 1...
Page 59: ...3 Reattach the application cover x1 1 Installation 58 1...
Page 65: ...2 Preventive Maintenance 64 2...
Page 72: ...Left Covers 1 Left upper cover A x4 2 Controller cover B x2 Covers and Common Procedures 71 3...
Page 82: ...Laser Unit 81 3...
Page 103: ...5 Cover C x2 6 Gear D x1 7 Lower paper feed unit E x2 x1 3 Replacement and Adjustment 102 3...
Page 128: ...Duplex Unit Duplex Cover Removal 1 Duplex unit cover A x4 Duplex Unit 127 3...
Page 181: ...4 Troubleshooting 180 4...
Page 289: ...Self Diagnostic Test Flow 5 Service Tables 288 5...
Page 306: ...Controller Block Diagram Board Layout 305 6...
Page 319: ...What Happens When a New Unit Is Detected 6 Details 318 6...
Page 367: ...6 Details 366 6...
Page 379: ...MEMO 378...
Page 380: ...MEMO 379...
Page 381: ...MEMO 380...