Toner Supply
Toner Bottle Replenishment Mechanism
When the toner bottle is installed in the bottle holder [A], pin [B] slides up the side of the PCU [C], pulling
out the toner shutter [D]. When the toner bottle holder lever [E] is returned to its original position, the cap
[F] pulls away and is kept in place by the chuck [G].
The toner bottle holder lever [E] cannot be lowered:
• Until a toner bottle is installed in the holder. This prevents toner falling out of the holder unit as a result
of lowering the handle with no toner bottle installed.
• Until the holder and bottle have been pushed into the machine completely and locked in place. Instruct
the customer to always follow the bottle replacement instructions of the new decal attached to the
toner bottle.
The toner bottle has a spiral groove which rotates the bottle to move toner to the development unit. When
the bottle holder unit is pulled out, the chuck [G] releases the toner bottle cap and the toner shutter [D]
closes and blocks the opening.
6. Details
328
6
Summary of Contents for A-P4
Page 1: ...Model A P4 Machine Code G147 SERVICE MANUAL May 12th 2006 Subject to change...
Page 27: ...Installation Flowchart 1 Installation 26 1...
Page 59: ...3 Reattach the application cover x1 1 Installation 58 1...
Page 65: ...2 Preventive Maintenance 64 2...
Page 72: ...Left Covers 1 Left upper cover A x4 2 Controller cover B x2 Covers and Common Procedures 71 3...
Page 82: ...Laser Unit 81 3...
Page 103: ...5 Cover C x2 6 Gear D x1 7 Lower paper feed unit E x2 x1 3 Replacement and Adjustment 102 3...
Page 128: ...Duplex Unit Duplex Cover Removal 1 Duplex unit cover A x4 Duplex Unit 127 3...
Page 181: ...4 Troubleshooting 180 4...
Page 289: ...Self Diagnostic Test Flow 5 Service Tables 288 5...
Page 306: ...Controller Block Diagram Board Layout 305 6...
Page 319: ...What Happens When a New Unit Is Detected 6 Details 318 6...
Page 367: ...6 Details 366 6...
Page 379: ...MEMO 378...
Page 380: ...MEMO 379...
Page 381: ...MEMO 380...