003
400dpi Init Set
400 dpi Initial Setting
Initializes the laser beam pitch for 400 dpi using the value for SP2-109-1.
After entering a value for SP2-109-1, this SP must be used.
004
600dpi Init Set
600 dpi Initial Setting
Initializes the laser beam pitch for 600 dpi using the value for SP2-109-2.
After entering a value for SP2-109-2, this SP must be used.
005
Auto Int Set
Auto Pitch Adjustment Interval
[50 ~ 65535 / 1000 / 1 step]
Sets the interval for automatic laser beam pitch adjustment.
When the number of times that the resolution has been changed reaches this value, the laser
unit position is automatically corrected.
006
LD Unit Position
Current LD Unit Position
Displays the current LD unit position (number of pulses from home position). If this is different
from the value of 2-109-1 or 2-109-2, LD unit positioning has failed.
007
Pitch Change Cnt
Beam Pitch Change Counter
Displays how many times the LD unit position has been changed (how many times the resolution
has changed.)
When the laser beam pitch adjustment is done, this counter is reset to zero.
008
Pitch Data Reset
Beam Pitch Data Reset
Resets the values of SP2-109-6 and SP2-109-7.
After replacing the LD unit, this SP mode must be performed. See the LD Unit Removal Procedure.
2110
Test Mode dpi DFU
[See below / 8/ 0 ~ 18]
Sets the resolution (dpi).
Any setting other than 0, 4, or 8 will cause an error.
0 = 400 x 400 dpi
4= 300 x 300 dpi
8= 600 x 600 dpi
Service Program Mode Tables
193
5
Summary of Contents for A-P4
Page 1: ...Model A P4 Machine Code G147 SERVICE MANUAL May 12th 2006 Subject to change...
Page 27: ...Installation Flowchart 1 Installation 26 1...
Page 59: ...3 Reattach the application cover x1 1 Installation 58 1...
Page 65: ...2 Preventive Maintenance 64 2...
Page 72: ...Left Covers 1 Left upper cover A x4 2 Controller cover B x2 Covers and Common Procedures 71 3...
Page 82: ...Laser Unit 81 3...
Page 103: ...5 Cover C x2 6 Gear D x1 7 Lower paper feed unit E x2 x1 3 Replacement and Adjustment 102 3...
Page 128: ...Duplex Unit Duplex Cover Removal 1 Duplex unit cover A x4 Duplex Unit 127 3...
Page 181: ...4 Troubleshooting 180 4...
Page 289: ...Self Diagnostic Test Flow 5 Service Tables 288 5...
Page 306: ...Controller Block Diagram Board Layout 305 6...
Page 319: ...What Happens When a New Unit Is Detected 6 Details 318 6...
Page 367: ...6 Details 366 6...
Page 379: ...MEMO 378...
Page 380: ...MEMO 379...
Page 381: ...MEMO 380...