04 Beta (Tray)
Adjusts the transfer current correction coefficient used if the paper width is less than the setting
of SP2309-02. DFU
[1.0 ~ 3 / 1.2 / 0.1 mm step]
05 Gamma (By-pass)
Adjusts the transfer current correction coefficient used if the paper width is less than the setting
of SP2309-01. DFU
[1.0 ~ 3 / 1.5 / 0.1 mm step]
06 Delta (By-pass)
Adjusts the transfer current correction coefficient used if the paper width is less than the setting
of SP2309-02. DFU
[1.0 ~ 3 / 1.5 / 0.1 mm step]
2801
TD Init. Setting
TD Sensor Initial Setting
Performs the TD sensor initial setting. This SP mode controls the voltage applied to the TD sensor
to make the TD sensor output about 4.0 V. Press “Execute” to start. After finishing this, the TD
sensor output voltage is displayed.
Use this mode only after installing the machine, changing the TD sensor, or adding new devel-
oper.
2802
TD Manual Set
TD Sensor Manual Setting
Allows you to adjust the TD sensor output manually for the following.
001
Initial Vt
[1.00 ~ 5.00V / 4.78V / 0.02V step]
Adjusts the TD sensor output (VT).
Change this value after replacing the development unit with another one that already contains
toner. For example, when using a development unit from another machine for test purposes. To
adjust VT, use a similar procedure as for SP2-220.
002
Vt Max
[1.00 ~ 5.00V / 4.78V / 0.02V step]
Adjusts the maximum value for SP2802 1.
003
Vt Min
[1.00 ~ 5.00V / 1.00V / 0.02V step]
Adjusts the minimum value for SP2802 1.
5. Service Tables
198
5
Summary of Contents for A-P4
Page 1: ...Model A P4 Machine Code G147 SERVICE MANUAL May 12th 2006 Subject to change...
Page 27: ...Installation Flowchart 1 Installation 26 1...
Page 59: ...3 Reattach the application cover x1 1 Installation 58 1...
Page 65: ...2 Preventive Maintenance 64 2...
Page 72: ...Left Covers 1 Left upper cover A x4 2 Controller cover B x2 Covers and Common Procedures 71 3...
Page 82: ...Laser Unit 81 3...
Page 103: ...5 Cover C x2 6 Gear D x1 7 Lower paper feed unit E x2 x1 3 Replacement and Adjustment 102 3...
Page 128: ...Duplex Unit Duplex Cover Removal 1 Duplex unit cover A x4 Duplex Unit 127 3...
Page 181: ...4 Troubleshooting 180 4...
Page 289: ...Self Diagnostic Test Flow 5 Service Tables 288 5...
Page 306: ...Controller Block Diagram Board Layout 305 6...
Page 319: ...What Happens When a New Unit Is Detected 6 Details 318 6...
Page 367: ...6 Details 366 6...
Page 379: ...MEMO 378...
Page 380: ...MEMO 379...
Page 381: ...MEMO 380...