SP No.
Name
Range
SP2802 002
TD Sensor Manual Setting – VTMAX
SP2802 003
TD Sensor Manual Setting – VTMIN
984
D
Print image data transfer error
• Controller board defective
• BICU defective
• Connectors between BICU
and controller loose or de-
fective
The image transfer from the controller to the engine via
the PCI bus does not end within 15 s after starting.
986
D
Software write parameter setting error
• Software defective
An unstable area at the storage destination in the set-
tings table is set NULL for the parameter received by
the write module.
990
D
Software error 1
The software performs an unexpected
function and the program cannot con-
tinue.
• Software defective, re-boot
*1
991
C
Software error 2
The software performs an unexpected
function. However, unlike SC990, re-
covery processing allows the program
to continue.
• Software defective, re-boot
*1
*1: There are two possible methods to get more details about SC990 and SC991:
1. Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most recent logged
errors.
2. If you press the zero key on the operation panel with the SP selection menu displayed, you will see
detailed information about the recently logged SC990 or SC991, including the software file name,
line number, and so on.
The first method in the above list is the recommended method, because another SC could write over the
information for the previous SC.
Service Call Conditions
173
4
Summary of Contents for A-P4
Page 1: ...Model A P4 Machine Code G147 SERVICE MANUAL May 12th 2006 Subject to change...
Page 27: ...Installation Flowchart 1 Installation 26 1...
Page 59: ...3 Reattach the application cover x1 1 Installation 58 1...
Page 65: ...2 Preventive Maintenance 64 2...
Page 72: ...Left Covers 1 Left upper cover A x4 2 Controller cover B x2 Covers and Common Procedures 71 3...
Page 82: ...Laser Unit 81 3...
Page 103: ...5 Cover C x2 6 Gear D x1 7 Lower paper feed unit E x2 x1 3 Replacement and Adjustment 102 3...
Page 128: ...Duplex Unit Duplex Cover Removal 1 Duplex unit cover A x4 Duplex Unit 127 3...
Page 181: ...4 Troubleshooting 180 4...
Page 289: ...Self Diagnostic Test Flow 5 Service Tables 288 5...
Page 306: ...Controller Block Diagram Board Layout 305 6...
Page 319: ...What Happens When a New Unit Is Detected 6 Details 318 6...
Page 367: ...6 Details 366 6...
Page 379: ...MEMO 378...
Page 380: ...MEMO 379...
Page 381: ...MEMO 380...