5055
Display IP add
Display IP Address
Switches the banner display of the IP address off and on. (Default: *Off)
[OFF] ON
For example, if this SP is switched on, the IP address will be displayed below "Ready" while
the printer is in standby mode:
Ready
169.254.187.055
5056
Coverage Counter
[0~1/0/1] 0:Not Displayed 1:Displayed
This SP switches the counter list for the system administrator on/off.
5104
Double Count
A3/DLT Double Count
Specifies whether the counter is doubled for A3/DLT. “Yes” counts except from the bypass
tray. When “Yes” is selected, A3 and DLT paper are counted twice, that is A4 x2 and LT x2
respectively.
5131
PaperTypeSelect
Paper Size Type Selection
0: Japan, 1: North America, 2: Europe
Selects the paper size (type) for paper. (Default depends on DIP SW 101 setting.)
After changing the setting, turn the machine off and on. If the paper size of the archive files
stored on the HDD is different, abnormal copies could result.
5150
Bypass Length Se
Bypass Length Setting
Sets up the by-pass tray for long paper.
[0~1/1]
0: Off
1: On. Sets the tray for feeding paper up to 600 mm long.
If this SP is set to ‘on’, paper jams are not detected in the paper path.
5179
By-pass Tray Pap
Bypass Paper Size Error
This SP determines whether a paper size error prompt appears when the machine detects the
wrong paper size for the job and jams during feed from the bypass tray.
Service Program Mode Tables
207
5
Summary of Contents for A-P4
Page 1: ...Model A P4 Machine Code G147 SERVICE MANUAL May 12th 2006 Subject to change...
Page 27: ...Installation Flowchart 1 Installation 26 1...
Page 59: ...3 Reattach the application cover x1 1 Installation 58 1...
Page 65: ...2 Preventive Maintenance 64 2...
Page 72: ...Left Covers 1 Left upper cover A x4 2 Controller cover B x2 Covers and Common Procedures 71 3...
Page 82: ...Laser Unit 81 3...
Page 103: ...5 Cover C x2 6 Gear D x1 7 Lower paper feed unit E x2 x1 3 Replacement and Adjustment 102 3...
Page 128: ...Duplex Unit Duplex Cover Removal 1 Duplex unit cover A x4 Duplex Unit 127 3...
Page 181: ...4 Troubleshooting 180 4...
Page 289: ...Self Diagnostic Test Flow 5 Service Tables 288 5...
Page 306: ...Controller Block Diagram Board Layout 305 6...
Page 319: ...What Happens When a New Unit Is Detected 6 Details 318 6...
Page 367: ...6 Details 366 6...
Page 379: ...MEMO 378...
Page 380: ...MEMO 379...
Page 381: ...MEMO 380...