11.1.2
Distances
General Information
In addition to the mounting dimensions, the devices of the Rexroth IndraDrive
range require additional mounting clearance:
●
To ventilate the devices
●
To mount accessories and connections
●
To take temperature limits of neighboring mounting parts, such as cable
ducts etc., into account
For the required mounting clearance in the control cabinet, take additional
distances between the devices and on their tops and bottoms into account.
For the distances to be complied with, d
top
(distance to top of device), d
bot
(distance to bottom of device) and d
hor
(distance to side of device), see Proj‐
ect Planning Manual "Rexroth IndraDrive Supply Units and Power Sec‐
tions" → Chapter of the respective device → "Technical Data" → "Mechanical
System and Mounting" → "Power Dissipation, Mounting Position, Cooling,
Distances"
Distance Between the Devices
Owing to power dissipation in the devices, especially due to integrated brak‐
ing resistors, the temperatures of neighboring devices are rising. In the case
of lateral mounting, trouble-free operation therefore requires the following
minimum distances (in mm) between the devices.
Minimum distance [mm]
Between
and
HCS02
HCS03
(HNK01,
HLR01)
HMV01
HMV02
HMS01 /
HMD01
HMS02
HCS02.1E
5
--
--
--
0 (HMS to the
right of HCS)
5 (HMS to the
left of HCS)
0 (HMS to the
right of HCS)
5 (HMS to the
left of HCS)
HCS03.1E with
HNK01 and HLR01
--
0
--
--
0
--
HMV01.1E /
HMV01.1R
--
--
0
--
0
--
HMS01.1 /
HMD01.1
0 (HMS to the
right of HCS)
5 (HMS to the
left of HCS)
0
0
--
0
--
HMV02.1R
--
--
--
--
--
0
HMS02.1
0 (HMS to the
right of HCS)
5 (HMS to the
left of HCS)
0
0
0
0
0
--
Not allowed
Tab.11-1:
Minimum Distances
Bosch Rexroth AG
DOK-INDRV*-SYSTEM*****-PR06-EN-P
Rexroth IndraDrive Drive Systems with HMV01/02 HMS01/02, HMD01, HCS02/03
190/309
Arranging the Components in the Control Cabinet